Conductive Carbon Black for Wire & Cable Compounds
Match published TDS columns for heat-tracing cables versus extra-high-voltage shielding and water-blocking tape — SP150, SP100B and 80P are not interchangeable here.
Conductive carbon black for wire and cable compounds should be shortlisted from the checked columns on the family conductive and antistatic TDS (printed 3 August 2025), not from a generic “cable grade” label. On that published map, acetylene grade SP150 is marked for heat-tracing cables and thermally conductive materials; it is not marked for extra-high-voltage cable shielding compounds or cable water-blocking tape. Acetylene grade SP100B is marked for heat-tracing cables, extra-high-voltage shielding compounds and cable water-blocking tape. Furnace grade 80P is marked for extra-high-voltage shielding compounds and cable water-blocking tape, and is not marked for heat-tracing cables. Ask for the family TDS, the EU REACH SDS and a sample via Contact or Sample & export once the compound type is clear.
Separate the cable job before you sample
Heat-tracing compounds, shielding compounds and water-blocking tapes share a factory floor but not one percolation target or one process window. Write down whether you are screening a heat-tracing compound, an extra-high-voltage shielding compound, a water-blocking tape or another construction; the host polymer; and any resistivity or cleanliness limit that already exists in the customer file. The family sheet lists additional rows that are also checked for some cable columns; we will point you to the ones that are actually marked rather than inventing unpublished grade pages.
Selection table from the published map
| Grade | Published figures | Cable-related map notes |
|---|---|---|
| SP150 | Acetylene. Oil absorption 220~270 ml/100g; iodine 85±10 g/kg; resistivity ≤0.25 Ω·cm; heating loss and ash each ≤0.50%; no published Fe figure | Marked for heat-tracing cables and thermally conductive materials. Not marked for extra-high-voltage cable shielding or cable water-blocking tape. |
| SP100B | Acetylene (B = beaded / granular). Oil absorption 180~220 ml/100g; iodine 75±5 g/kg; resistivity ≤0.25 Ω·cm; Fe ≤30 ppm; heating loss ≤0.30%; ash ≤0.20% | Marked for heat-tracing cables, extra-high-voltage cable shielding and cable water-blocking tape, and for thermally conductive materials. Not marked for the three battery columns. |
| 80P | Furnace powder. Oil absorption 440~530 ml/100g; iodine 330±40 g/kg; heating loss ≤1.5%; ash ≤0.5%; pH 7~9; no published resistivity or Fe | Marked for extra-high-voltage cable shielding compounds and cable water-blocking tape. Not marked for heat-tracing cables or the three battery columns. |
If the brief is plastics packaging rather than a cable compound, use conductive carbon black for plastics. Battery electrode columns belong to SP150-Li and EV battery notes, not this page.
What we do not claim
This page does not assign extra-high-voltage shielding performance to SP150, and it does not invent a resistivity number for 80P. It also does not publish voltage-class ratings, compound recipes or competitive “drop-in” claims against unnamed cable blacks. Those belong in a technical discussion after you share the construction and the test method.
Is SP150 suitable for extra-high-voltage cable shielding?
Not according to the published application map. That column is not checked for SP150. If shielding is the job, start from the rows that are actually marked — on the pages published here, that discussion includes SP100B and 80P — and tell us the construction so we can point to any other checked rows on the same sheet.
Is 80P a heat-tracing grade?
The map does not mark 80P for heat-tracing cables. That column is checked on SP150 and SP100B. Use the checked column rather than assuming every conductive grade covers every cable construction.
What should a cable-compound RFQ include?
Construction type (heat-tracing, shielding, water-blocking or other), polymer system, any resistivity or cleanliness target, sample size, and whether you need TDS, SDS and COA fields. WhatsApp and phone: +86 150-8314-1412. We do not list MOQ or Incoterms on this page.
Request a sample or quote · Sample & export · SDS, specs and export documents
Last updated: November, 2026